UCM601 UHF RFID Reader Module SDK
UCM601 UHF RFID reader module SDK guide covering serial packets, EPC Gen2 inventory, tag access, RF configuration, errors, and code examples.
Use this guide to integrate the UCM601 single-antenna UHF RFID reader module or finished reader with an MCU, Linux or Windows computer, Android device, or other serial host.
The protocol is based on UCChip UHF Reader Serial Protocol V1.2.3. Commands shared with UCM602/UCM606/UCM608 are included for reference, but family-specific commands are not automatically supported by UCM601.
Serial packet format
Head
1 byte
Always 0xA0
Len
1 byte
Data length + 3; excludes Head and Len
Address
1 byte
Reader address; 0x00 is the common address
Cmd
1 byte
Command code
Data
0โN bytes
Parameters or response payload
Checksum
1 byte
8-bit LRC over all preceding bytes
A complete valid frame has a byte sum of zero modulo 256:
checksum = (-sum(frame_without_checksum)) & 0xFFExample: get firmware version (0x72) from address 0x00:
A0 03 00 72 EBMinimal Python SDK
import serial
HEAD = 0xA0
def build_frame(command: int, data: bytes = b"", address: int = 0) -> bytes:
frame = bytes((HEAD, len(data) + 3, address, command)) + data
return frame + bytes(((-sum(frame)) & 0xFF,))
def read_frame(port: serial.Serial) -> tuple[int, int, bytes]:
while port.read(1) != bytes((HEAD,)):
pass
length = port.read(1)[0]
body = port.read(length)
frame = bytes((HEAD, length)) + body
if len(body) != length or sum(frame) & 0xFF:
raise ValueError("Invalid UCM601 frame length or checksum")
return body[0], body[1], body[2:-1]
with serial.Serial("/dev/ttyUSB0", 115200, timeout=1) as port:
port.write(build_frame(0x72))
address, command, data = read_frame(port)
major, minor, model = data
assert model == 0x01 # UCM601
print(f"firmware={major}.{minor}")Do not interpret every response as a one-byte status. Inventory and tag-access commands return structured records, and continuous inventory produces multiple frames.
Recommended initialization
Open UART at 115200, 8 data bits, no parity, 1 stop bit, unless the product configuration says otherwise.
Send
0x72; verify model byte0x01for UCM601.Read or set the frequency region with
0x79/0x78.Set antenna 1 with
0x74, payload01.Set power with
0x76; never exceed decimal 20 (0x14) on UCM601.Select an RF link profile with
0x69if required.Send
0x4Aafter changes that must survive power loss.Start inventory with
0x8Bor0x89; stop with0x8Cbefore tag access or reconfiguration.
Reader and RF commands
0x4A
Save parameters
Save once after grouped changes
0x4B
Restore defaults
No response
0x66
Temporary RF power
3โ20 dBm; not saved
0x69 / 0x6A
Set/get RF link profile
Set restarts reader and saves
0x70
Reset reader
Standard status response
0x71
Set UART baud rate
Takes effect immediately
0x72
Get firmware/model
UCM601 model is 0x01
0x73
Set reader address
0x00โ0xFF
0x74 / 0x75
Set/get antenna
Use antenna 0x01
0x76 / 0x77
Set/get RF power
Maximum 20 dBm
0x78 / 0x79
Set/get frequency region
Preset or custom
0x7A / 0x7B
Buzzer / temperature
Temperature has sign and magnitude
0xF3
Read UUID
Confirm firmware support
EPC Gen2 / ISO 18000-6C commands
0x80
Inventory into buffer
Ant; use 01
0x81
Read tag
MemBank + WordAdd[4] + WordCnt[2] + Password[4]
0x82
Write tag
Password[4] + MemBank + WordAdd[4] + WordCnt[2] + data
0x83
Lock memory
Password[4] + MemBank + LockType
0x84
Kill tag
KillPassword[4]
0x85 / 0x86
Set/get EPC match
Limit ACCESS to a selected EPC
0x89
Real-time inventory
Reports tags without buffering
0x8A
Inventory and read data
Antenna, rounds, match mode
0x8B
Session/Target inventory
Recommended inventory command
0x8C
Stop inventory
No success response
0x8D / 0x8E
Set/get Select
Gen2 Select mask/action
0x90 / 0x91
Read buffer
0x91 clears after retrieval
0x92 / 0x93
Buffer count/clear
Distinct-tag count / reset
Memory banks: 0 = RESERVED, 1 = EPC, 2 = TID, 3 = USER. Addresses and counts are 16-bit words. EPC writes normally start at word 2, after CRC and PC.
Inventory example
The protocol returns 0x8B inventory reports under command 0x89. Handle repeated frames, partial serial reads, unsolicited 0xE1 overtemperature alarms, and intentional no-response commands.
Frequency regions
FCC
0x01
902โ928 MHz
ETSI
0x02
865โ868 MHz
CHN-1
0x03
840โ845 MHz
Custom
0x04
Explicit spacing/count/start frequency
CHN-2
0x05
920โ925 MHz
Custom payload: 04 + FreqSpace[2] + FreqQuantity[1] + StartFreq[3]. Spacing and big-endian start frequency are in kHz. Quantity 1 selects a fixed frequency.
Baud-rate IDs
00
1200
07
57600
01
2400
08
76800
02
4800
09
115200
03
9600
0A
128000
04
14400
0B
230400
05
19200
0C
256000
06
38400
0D
460800
Common status and errors
10
Success
11
Execution failed
12
Custom inventory complete
13
Antenna polling complete
22
Antenna disconnected
25
RF power setting error
31
Inventory error
32
Tag read error
33
Tag write error
34
Tag lock error
35
Tag kill error
36
No tag available
37
Inventory succeeded, access failed
38
No EPC buffer data
40
Access/password error
41
Invalid parameter
42
Word count too large
43
Memory bank out of range
46
Invalid address
47
Antenna out of range
48
Power out of range
49
Region out of range
4A
Baud rate out of range
4F
Invalid frequency range
53
RF chip not responding
54
Requested power not reached
60
Insufficient tag power
61
Insufficient permissions
62
Memory address out of range
63
Tag memory locked
64
Incorrect tag password
65
Authentication failed
The protocol also defines GB, SM7, heartbeat, TX timing, GPIO, firmware-upgrade, and multi-antenna commands. Treat them as optional until confirmed on the exact UCM601 firmware. A few source sections conflict on error-code meanings and packet fields; log the complete raw frame and firmware version when debugging.
Integration checklist
Buffer bytes and parse by
Head + Len; one UART read may contain a partial frame or several frames.Reject invalid length/LRC before interpreting data.
Select the response structure by command, not only the first data byte.
Stop continuous inventory before read/write/lock/kill operations.
Add timeouts for commands designed to return no response.
Limit Flash writes; use
0x66for frequent temporary power changes.Enforce local band rules and UCM601's 20 dBm ceiling.
Require confirmation for lock, kill, reset, and firmware upgrade.