> For the complete documentation index, see [llms.txt](https://docs.mtoolstec.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.mtoolstec.com/hardware/rfid-nfc-and-uhf-hardware/ucm601-uhf-rfid-reader-module-sdk.md).

# UCM601 UHF RFID Reader Module SDK

UCM601 UHF RFID reader module SDK guide covering serial packets, EPC Gen2 inventory, tag access, RF configuration, errors, and code examples.

Use this guide to integrate the **UCM601 single-antenna UHF RFID reader module or finished reader** with an MCU, Linux or Windows computer, Android device, or other serial host.

The protocol is based on UCChip UHF Reader Serial Protocol V1.2.3. Commands shared with UCM602/UCM606/UCM608 are included for reference, but family-specific commands are not automatically supported by UCM601.

{% hint style="info" %}
**UCM601 limits:** one antenna, RF output up to **20 dBm**, command UART default **115200 bps**, reader address `0x00`, and factory frequency region FCC 902–928 MHz. Confirm the legal UHF RFID band for the deployment country before enabling RF output.
{% endhint %}

## Serial packet format

| Field    |      Size | Description                                  |
| -------- | --------: | -------------------------------------------- |
| Head     |    1 byte | Always `0xA0`                                |
| Len      |    1 byte | Data length + 3; excludes Head and Len       |
| Address  |    1 byte | Reader address; `0x00` is the common address |
| Cmd      |    1 byte | Command code                                 |
| Data     | 0–N bytes | Parameters or response payload               |
| Checksum |    1 byte | 8-bit LRC over all preceding bytes           |

A complete valid frame has a byte sum of zero modulo 256:

```
checksum = (-sum(frame_without_checksum)) & 0xFF
```

Example: get firmware version (`0x72`) from address `0x00`:

```
A0 03 00 72 EB
```

## Minimal Python SDK

```python
import serial

HEAD = 0xA0

def build_frame(command: int, data: bytes = b"", address: int = 0) -> bytes:
    frame = bytes((HEAD, len(data) + 3, address, command)) + data
    return frame + bytes(((-sum(frame)) & 0xFF,))

def read_frame(port: serial.Serial) -> tuple[int, int, bytes]:
    while port.read(1) != bytes((HEAD,)):
        pass
    length = port.read(1)[0]
    body = port.read(length)
    frame = bytes((HEAD, length)) + body
    if len(body) != length or sum(frame) & 0xFF:
        raise ValueError("Invalid UCM601 frame length or checksum")
    return body[0], body[1], body[2:-1]

with serial.Serial("/dev/ttyUSB0", 115200, timeout=1) as port:
    port.write(build_frame(0x72))
    address, command, data = read_frame(port)
    major, minor, model = data
    assert model == 0x01  # UCM601
    print(f"firmware={major}.{minor}")
```

Do not interpret every response as a one-byte status. Inventory and tag-access commands return structured records, and continuous inventory produces multiple frames.

## Recommended initialization

1. Open UART at **115200, 8 data bits, no parity, 1 stop bit**, unless the product configuration says otherwise.
2. Send `0x72`; verify model byte `0x01` for UCM601.
3. Read or set the frequency region with `0x79` / `0x78`.
4. Set antenna 1 with `0x74`, payload `01`.
5. Set power with `0x76`; never exceed decimal 20 (`0x14`) on UCM601.
6. Select an RF link profile with `0x69` if required.
7. Send `0x4A` after changes that must survive power loss.
8. Start inventory with `0x8B` or `0x89`; stop with `0x8C` before tag access or reconfiguration.

{% hint style="warning" %}
`0x69` restarts the reader and saves directly to Flash. `0x71` and `0x73` take effect immediately. `0x4B` restores defaults and sends no response.
{% endhint %}

## Reader and RF commands

| Cmd             | Function                 | UCM601 notes                       |
| --------------- | ------------------------ | ---------------------------------- |
| `0x4A`          | Save parameters          | Save once after grouped changes    |
| `0x4B`          | Restore defaults         | No response                        |
| `0x66`          | Temporary RF power       | 3–20 dBm; not saved                |
| `0x69` / `0x6A` | Set/get RF link profile  | Set restarts reader and saves      |
| `0x70`          | Reset reader             | Standard status response           |
| `0x71`          | Set UART baud rate       | Takes effect immediately           |
| `0x72`          | Get firmware/model       | UCM601 model is `0x01`             |
| `0x73`          | Set reader address       | `0x00`–`0xFF`                      |
| `0x74` / `0x75` | Set/get antenna          | Use antenna `0x01`                 |
| `0x76` / `0x77` | Set/get RF power         | Maximum 20 dBm                     |
| `0x78` / `0x79` | Set/get frequency region | Preset or custom                   |
| `0x7A` / `0x7B` | Buzzer / temperature     | Temperature has sign and magnitude |
| `0xF3`          | Read UUID                | Confirm firmware support           |

## EPC Gen2 / ISO 18000-6C commands

| Cmd             | Function                 | Main request data                                        |
| --------------- | ------------------------ | -------------------------------------------------------- |
| `0x80`          | Inventory into buffer    | `Ant`; use `01`                                          |
| `0x81`          | Read tag                 | `MemBank + WordAdd[4] + WordCnt[2] + Password[4]`        |
| `0x82`          | Write tag                | `Password[4] + MemBank + WordAdd[4] + WordCnt[2] + data` |
| `0x83`          | Lock memory              | `Password[4] + MemBank + LockType`                       |
| `0x84`          | Kill tag                 | `KillPassword[4]`                                        |
| `0x85` / `0x86` | Set/get EPC match        | Limit ACCESS to a selected EPC                           |
| `0x89`          | Real-time inventory      | Reports tags without buffering                           |
| `0x8A`          | Inventory and read data  | Antenna, rounds, match mode                              |
| `0x8B`          | Session/Target inventory | Recommended inventory command                            |
| `0x8C`          | Stop inventory           | No success response                                      |
| `0x8D` / `0x8E` | Set/get Select           | Gen2 Select mask/action                                  |
| `0x90` / `0x91` | Read buffer              | `0x91` clears after retrieval                            |
| `0x92` / `0x93` | Buffer count/clear       | Distinct-tag count / reset                               |

Memory banks: `0 = RESERVED`, `1 = EPC`, `2 = TID`, `3 = USER`. Addresses and counts are 16-bit words. EPC writes normally start at word 2, after CRC and PC.

## Inventory example

```python
# S1, Target A, antenna 1
port.write(build_frame(0x8B, bytes.fromhex("01 00 01")))

while scanning:
    address, command, data = read_frame(port)
    if command == 0x89:
        # Ant[1] + PC[2] + EPC[*] + RSSI[4] + Freq[3]
        handle_inventory_report(data)

# Success intentionally has no response.
port.write(build_frame(0x8C))
```

The protocol returns `0x8B` inventory reports under command `0x89`. Handle repeated frames, partial serial reads, unsolicited `0xE1` overtemperature alarms, and intentional no-response commands.

## Frequency regions

| Region |  Value | Nominal band                           |
| ------ | -----: | -------------------------------------- |
| FCC    | `0x01` | 902–928 MHz                            |
| ETSI   | `0x02` | 865–868 MHz                            |
| CHN-1  | `0x03` | 840–845 MHz                            |
| Custom | `0x04` | Explicit spacing/count/start frequency |
| CHN-2  | `0x05` | 920–925 MHz                            |

Custom payload: `04 + FreqSpace[2] + FreqQuantity[1] + StartFreq[3]`. Spacing and big-endian start frequency are in kHz. Quantity 1 selects a fixed frequency.

## Baud-rate IDs

|   ID |   bps |   ID |    bps |
| ---: | ----: | ---: | -----: |
| `00` |  1200 | `07` |  57600 |
| `01` |  2400 | `08` |  76800 |
| `02` |  4800 | `09` | 115200 |
| `03` |  9600 | `0A` | 128000 |
| `04` | 14400 | `0B` | 230400 |
| `05` | 19200 | `0C` | 256000 |
| `06` | 38400 | `0D` | 460800 |

## Common status and errors

| Code | Meaning                            | Code | Meaning                     |
| ---: | ---------------------------------- | ---: | --------------------------- |
| `10` | Success                            | `11` | Execution failed            |
| `12` | Custom inventory complete          | `13` | Antenna polling complete    |
| `22` | Antenna disconnected               | `25` | RF power setting error      |
| `31` | Inventory error                    | `32` | Tag read error              |
| `33` | Tag write error                    | `34` | Tag lock error              |
| `35` | Tag kill error                     | `36` | No tag available            |
| `37` | Inventory succeeded, access failed | `38` | No EPC buffer data          |
| `40` | Access/password error              | `41` | Invalid parameter           |
| `42` | Word count too large               | `43` | Memory bank out of range    |
| `46` | Invalid address                    | `47` | Antenna out of range        |
| `48` | Power out of range                 | `49` | Region out of range         |
| `4A` | Baud rate out of range             | `4F` | Invalid frequency range     |
| `53` | RF chip not responding             | `54` | Requested power not reached |
| `60` | Insufficient tag power             | `61` | Insufficient permissions    |
| `62` | Memory address out of range        | `63` | Tag memory locked           |
| `64` | Incorrect tag password             | `65` | Authentication failed       |

The protocol also defines GB, SM7, heartbeat, TX timing, GPIO, firmware-upgrade, and multi-antenna commands. Treat them as optional until confirmed on the exact UCM601 firmware. A few source sections conflict on error-code meanings and packet fields; log the complete raw frame and firmware version when debugging.

## Integration checklist

* Buffer bytes and parse by `Head + Len`; one UART read may contain a partial frame or several frames.
* Reject invalid length/LRC before interpreting data.
* Select the response structure by command, not only the first data byte.
* Stop continuous inventory before read/write/lock/kill operations.
* Add timeouts for commands designed to return no response.
* Limit Flash writes; use `0x66` for frequent temporary power changes.
* Enforce local band rules and UCM601's 20 dBm ceiling.
* Require confirmation for lock, kill, reset, and firmware upgrade.

{% hint style="warning" %}
Use read, write, lock, kill, and security-testing functions only with tags and systems you own or are explicitly authorized to test. Lock, kill, firmware upgrade, and factory reset may be irreversible or interrupt service.
{% endhint %}